To clear the average values follow these steps:
1. Press and hold (6 seconds) the On/Off button to set the system mode to OFF
2. Using the “+” and “-“ buttons set the temperature set-point to 90°F.
When the display stops
flashing, press and hold
(8 seconds) the Select
button until “Unlo”
disappears from the
display.
14. Lock the Thermostat’s Buttons
Lock the thermostat’s buttons to prevent any unwanted changes made by any unauthorized person.
Lock the thermostat
Press the On/Off button to turn the
thermostat ON
Press and hold (25 seconds) the Select
button until “LOC” appears on display.
Unlock the thermostat
Press and hold (25 seconds) the Select
button until “UnLO” appears on display.
Press the Select button 2 more times to return to normal display mode.